Influence of sudden increasing of steam injection flow rate on coking furnace operation and the compensation method

Zhang Weiyong,Huang Dexian,Wang Yudong,Xiong Zhengqiu,Gong Huachu,Li Hua
DOI: https://doi.org/10.3969/j.issn.1001-4160.2007.04.010
2007-01-01
Abstract:Coking furnace performance is critical to the safety and long period running of delayed coking unit. The steam injection system is subject to sudden steam increasing in a refinery coker unit. The response of the outlet temperature to the sudden steam increasing is a large inverse response. When under PID control or not handled properly in manual control, the outlet temperature has a large deviation above its normal value, which results in high coking rate in furnace tubes and affects the safety and long period running of the whole unit. By analyzing the operating data, a rule based monitoring method that combines the information of steam, feed flow rate and feed pressure is proposed to judge the event of sudden steam increasing. Then an expert control strategy simulating the skilled operator is developed. The main purpose is to prevent the temperature from violating the upper limit. Field control results show that the monitoring and control methods are effective.
What problem does this paper attempt to address?