Treatment of humeral intercondylar fractures with AO locking plate:a retrospective study of 31 patients

Pan Sihua,Liu Xinwei,Ji Fang,Li Ming,Xu Shuogui
DOI: https://doi.org/10.3969/j.issn.1674-1439.2010.02.005
2010-01-01
Abstract:Objective To investigate the effects of AO locking plate on the humeral intercondylar fractures.Methods From January 2006 to June 2008,31 patients with humeral intercondylar fractures were treated.According to AO/ ASIF classification,there were 7 cases in C1,18 in C2 and 6 in C3.Posterior approach of elbow and trans-olecranon osteotomy were performed and internal fixation was applied with AO locking plate.The patients bagan the active training of elbow joint as soon as possible postoperatively.Results The 31 patients were followed up for 8 to 36 months and the average time was 14.8 months.Bone union was obtained in all cases.According to Cassebaum Score,the satisfactory rate of treatment was 83.9%(best in 9 cases,better in 17,good in 4,and bad in 1).Conclusion Through posterior approach of elbow and trans-olecranon osteotomy,application of AO locking plate is a good method for humeral intercondylar fracture.