Experimental Study on the Influence of Perforated Pipe on Performance of SCR Convertor Muffler Assembly

Chen Zhen,Lu Guodong,Zhao Yanguang,Hua Lun,Hu Jing,Shuai Shijin
DOI: https://doi.org/10.3969/j.issn.1671-0630.2011.06.006
2011-01-01
Abstract:Perforated pipe has been widely applied in the design of mufflers.The perforated pipe upstream of SCR catalyst has significant effect on the pressure loss and NOx conversion efficiency of SCR Convertor Muffler Assembly.In the study,two perforated pipes are designed.The effects of the structure and mounting position of the perforated pipes on the performance of SCR Convertor and Muffler Assembly are studied.The pressure loss and NOx concentration are measured separately using mercury U tube and Fourier Transform Infrared(FTIR) Spectroscopy.The experimental results show that,the pressure loss caused by the perforated pipe with large porosity with holes facing the SCR substrate is low.The structure and mounting position of the perforated pipes have significant effect on the NOx conversion efficiency of SCR Convertor Muffler Assembly.The difference of NOx conversion efficiency is above 10 percent under some operating conditions.
What problem does this paper attempt to address?