Research on Characteristic of Mode Switch of Separate Meter in and Meter out Load Sensing Control System

XU Bing,ZENG Ding-rong,GE Yao-zheng,LIU Ying-jie
DOI: https://doi.org/10.3785/j.issn.1008-973x.2011.05.014
2011-01-01
Abstract:Conventional Load Sensing(LS) system has low efficiency when multiple actuators with different loads are in motion simultaneously,in order to improve system efficiency,the work mode switch controller of a novel separate meter in and separate meter out(SMISMO)-LS system was studied.The characteristics of energy consumption and velocity control in different work modes for heavy load actuator and light load actuator were compared through theoretical derivation,and work mode selection criterion and work mode switch controller for corresponding actuators were designed with aim to reduce energy consumption,experiments were carried on to test the effectiveness of the designed mode switch controller.The oscillations of velocity and back chamber pressure are low during mode switch process,back chamber pressure is maintained at low value to improve energy saving characteristic.Obtained results show that the work mode switch controller is feasible,and SMISMO-LS system can further improve energy saving characteristic while retaining good velocity control characteristic.
What problem does this paper attempt to address?