Analysis of five pesticide residues in water samples by using laboratory-made solid-phase microextraction device

LIU De-cang,HE Juan,GAO Hui-yun,LV Rui-he,CHENG Jie,LU Kui
DOI: https://doi.org/10.3969/j.issn.1000-0720.2009.02.015
2009-01-01
Abstract:An acrylate-based polymer was prepared and applied as a new fiber coating for solid-phase microextraction (SPME) for five pesticide residues from water samples. The efficiency of new coating was investigated by using a laboratory-made SPME device and gas chromatograph/mass spectrometer (GC/MS). The device was inexpensive and prepared simply. The optimum conditions for obtaining extraction efficiency, such as adsorption time and temperature, the desorption parameters, ionic strength and the pH values were investigated. The correlation coefficients (r) for the linear dynamic range from 1 to 1000 μg/L exceeded 0.99. The detection limits obtained were between 0.391 and 1.170 ng/L. In comparison with commercial coating (PA), the results showed that the complex coating had superior sorption capacity and the minimum detection limit lower than commercial coating (PA) with 2.96 ng/L for five pesticides in water samples.
What problem does this paper attempt to address?