[Efficacy of subarachnoid space protection in intracranial operation: a report of 156 cases].

Jie Zhao,Zhixiong Liu,Jinfang Liu,Dun Yuan,Yunsheng Liu,Xianrui Yuan
DOI: https://doi.org/10.3969/j.issn.1672-7347.2010.10.013
2010-01-01
Abstract:OBJECTIVE:To determine the efficacy of subarachnoid space protection in intracranial operation. METHODS:Data collected from 156 consecutive cranial operations, in which subarachnoid space protective technology was prophylacticly used, were analyzed. RESULTS:Fourteen patients had a postoperative fever for more than 1 week and 16 patients who required lumbar puncture to release blood contaminated cerebro-spinal fluid (CSF) or exclude meningitis. All except 3 patients were discharged as expected. No patients had symptomatic vasospasm and hydrocephalus. CONCLUSION:The subarachnoid space protective technology has good effect on preventing postoperative fever and improving the outcome of patients.