Abstract:The on-site calibration of fiber optical current transformer is often influenced by the environmental factors, resulting in certain deviation of results. We proposed the sources of uncertainty in this paper, which mainly include: the uncertainty uA(ε) induced by the error of standard FOCT, the uncertainty uB(ε) induced by the field environment and improper operation method, and the uncertainty uC(ε) induced by the calibrator unit. In further, the uB(ε) is analyzed detailed. This component is mainly produced by temperature, vibration and inhomogeneous magnetic field. The experimental results show that the errors of temperature, vibration and inhomogeneous magnetic field are 0.020%, 0.051% and 0.049%, respectively. Finally, we can calculate the synthetic standard uncertainty and expanded uncertainty of the DC calibration (P=99%) are 4.8×10-4 and 1.4×10-3, respectively. And the synthetic standard uncertainty and expanded uncertainty of the AC calibration (P=99%) are 5.6×10-4 and 1.6×10-3 respectively. The results show that the scheme can satisfy the uncertainty requirements of the direct comparison method (0.5S level).