RP-HPLC Determination of Dihydroartemisinin Content in Oil/Water Dihydroartemisinin Lipid Emulsion

Wang Ying,Ma Yufan,Lu Tingli,Chen Tao
DOI: https://doi.org/10.3969/j.issn.1006-4931.2013.18.024
2013-01-01
Abstract:Objective To establish a HPLC method to determine the content of dihydroartemisinin(DHA)in Oil/Water DHA Lipid Emulsion.Methods The Agilent HC C18 column(250 mm×4.6 mm,5 μm)was adopted,the mobile phase was acetonitrile-water(60:40),the flow rate was set at 1.0 mL/min,the column temperature was 25 ℃ and the wavelength was 216 nm.Results The mass concentration of DHA in the range of 0.002 129-2.18 mg/mL at the detection wavelength of 216 nm had good linear correlation with the area of the test peak,the average recovery rate was 95.32%(RSD=1.2).Conclusion This method is simple and precise with high recovery rate,high accuracy and good reproducibility,which can be used for the determination of the DHA content in Oil/Water DHA Lipid Emulsion.