TREATMENT OF ANIONIC SURFACTANT WASTEWATER BY THREE-DIMENSIONAL ELECTRODE REACTOR

Guo Yu-Feng,Wang Zhen-chuan,Li Jing-yin,Li Min,Wang Jun
DOI: https://doi.org/10.3969/j.issn.1000-3770.2006.05.007
2006-01-01
Abstract:Treatment of anionic surfactant (LAC) wastewater by three-dimensional electrolysis method was studied. The effect of different electrodes, voltage, retention time, electrodes interval and pH on degradation was also inspected, and the treating mechanism was discussed. It was found that when the treatment of wastewater containing anionic surfactants (LAC) was under the optimal conditions, i.e., electrodes interval of 2cm, treating voltage 8V, and the retention time of 40min,the removal rate of LAS, COD and TOC was over 94.5% ,66.2%,58.7% respectively.
What problem does this paper attempt to address?