Radiofrequency ablation for typical atrial flutter under the guidance of non-contact mapping system

Su Hao,Yan Ji,Xu Jian
DOI: https://doi.org/10.3969/j.issn.1000-0399.2012.11.008
2012-01-01
Abstract:Objective To explore the radiofrequency ablation for typical atrial flutter under the guidance of non-contact mapping system.Methods Twenty-five cases of typical atrial flutter patients had been definitely diagnosed based on the body surface 12-lead ECG and Holter,including 17 cases of paroxysmal atrial flutter and 8 of persistent atrial flutter.All patients had oral administration of 2 or more anti-arrhythmic therapeutics with poor effect.10-poles coronary sinus and right ventricular electrode were routinely placed,and ARRAY balloon was placed in the lower right atrium.The right atrial model was constructed,followed by ablating the tricuspid isthmus under the guidance of non-contact mapping system.Results All patients received successful ablation.Atrial flutter was terminated during the ablation in 18 cases,and 7 patients were in sinus rhythm under ablation.The delayed two-way conduction time was noted during pacing proximal coronary sinus and low right atrium respectively after surgery,no excitement was detected through the isthmus ablation line,and isthmus block was confirmed.Only one patient encountered recurrence of atrial flutter in the period of 6 to 18 months follow-up,and the recurrence rate was found to be 4.0%.Conclusion Non-contact mapping system guided radiofrequency ablation of typical atrial flutter therapy is safe and reliable,and can reduce X-ray exposure time and discharge cycles.