The Assess of Spiral CT Dacryocystography in the Diagnosis of Lacrimal Pathway Obstruction after Naso-Orbital-ethmoid Fracture

艾松涛,潘懿范,肖彩雯,范先群,陶晓峰,范新东
DOI: https://doi.org/10.3969/j.issn.1000-0313.2013.04.006
2013-01-01
Abstract:Objective:To assess the value of spiral CT dacryocystography in the diagnosis of lacrimal pathway obstruction after naso-orbital-ethmoid fracture.Methods:33 patients had clinical symptoms of dacryo-stenosis for more than 6 months after naso-orbital-ethmoid(NOE) fracture underwent spiral CT dacryocystography with multi-planer reformation(MPR),the images were analyzed.The fractures and bony structures of lacrimal pathway were assessed,and the incidence of various obstruction position of lacrimal system was evaluated and analyzed.Results:The medial wall of nasolacrimal duct(54.84%) and posterior lacrimal crest(51.61%) were the commonest position of fracture of lacrimal system.The majority of obstruction after NOE fracture was at the junction of lacrimal sac and nasolacrimal duct(33.33%,14/42),and the second predilection site of obstruction was the upper segment of nasolacrimal duct(28.57%,12/42).There was significant difference between the angle formed by the sagittal plane and the axis of nasolacrimal duct of injured side compared with that of the normal(t=-3.43,P=0.0023).On the other hand,there was no significant difference between the angle formed by the axial plane and normal/injured side of nasolacrimal duct(t=-2.06,P0.05).Conclusion:The bony structure and obstruction of lacrimal system could be clearly assessed by spiral CT dacryocystography with MPR post-processing technique,which is very valuable in surgical treatment of lacrimal obstruction after NOE fracture.
What problem does this paper attempt to address?