The Application Study Based on the Permeability Measurement Models of Tight Cores

GAO Cheng,XU Rui-Na,XUE Hua-Qing,JIANG Pei-Xue
2013-01-01
Journal of Engineering Thermophysics
Abstract:The conventional methods to measure the tight core which the permeability is less than 10~(-17) m~2 are limited.The transient pressure pulse decay method is a kind of means that is low-cost,easy of operation and widely used among the various methods to obtain the low permeability of a tight core.This paper was indicated to illustrate the principle of this measurement method,theoretical results and the comparisons of the data calculated by three main models.The results showed that all the data calculated by the three models were in good agreement with the data obtained from the gas permeability apparatus which was produced by the Core Lab Company.The Jones model and API model are more accurate when the gas adsorption can be ignored.CUI model should be selected when considering gas adsorption effect.In addition,the value of the parameter related to the gas adsorption effect should be determined carefully.
What problem does this paper attempt to address?