Experimental Study on Effects of Electrode Gaps on the High-current Vacuum Arc Voltage and the Rotation Speed of Anode Melting Pool

WANG Lijun,WANG Liuhuo,JIA Shenli,YANG Dingge,GAO He,SHI Zongqian
DOI: https://doi.org/10.13334/j.0258-8013.pcsee.2010.25.015
2010-01-01
Abstract:High-current (10 kA rms,20 kA rms) vacuum arc experiments were conducted in a detachable vacuum chamber for copper cup axial magnetic field (AMF) contacts with the electrode gaps of 10,16 and 20 mm. The vacuum arc appearance and the rotation speed of melting pool were observed with the high-speed CCD video camera,and the arc voltage waveforms were measured at the same time. Based on the experimental measurement,the high-current vacuum arc voltage and characteristics of melting pool rotation on AMF contacts with different electrode gaps were analyzed. Experimental results showed that the arc tends to be unstable and the arc voltage gradually increases with increasing of the electrode gap,so do the radius and the rotation speed of the anode surface melting pool. The rotation speed of the anode melting pool is about 0.664 m/s and the metal pool's radius is about 14.5 mm with the electrode gap of 10 mm. In contrast,the rotation speed of anode melting pool is about 1.204 m/s and the melting pool's radius is about 15.6 mm with the electrode gap of 16 mm.
What problem does this paper attempt to address?