Comparative Study on the Ways of Cardiac Function Evaluation in Rat Myocardial Infarction Models
Zhu Dan,Guo Yan-hong,Mi Lin
DOI: https://doi.org/10.3969/j.issn.1009-6604.2009.05.010
2009-01-01
Abstract:Objective To compare the characteristics of two tools for evaluating the rat's cardiac function after myocardial infarction,and to confirm the stage when stable heart failure is established after myocardial infarction.Methods We established rat myocardial infarction models with ligature of the left coronary artery.The rats were divided into five groups,four of the groups were fed for 2,4,6,or 8 weeks after the surgery(operation group),while another group was set as a sham-operated group,and was fed for 4 weeks.After the process,the rats received intraperitoneal injection of anesthetics,and a small ultrasonography instrument was used to carry out two-dimensional,M-mode echocardiography examination and determine the mitral flow spectrum.To measure the left ventricular end-systolic pressure(LVSP) and other hemodynamic parameters,a catheter was inserted through the carotid artery into the left ventricle.Finally,the heart of the rats was resected for weighing.The cardiac function of the 5 groups were analyzed and compared. Results The cardiac function of the rat models did not change within the first 2 weeks after the ligature of the left coronary artery(P>0.05).After that,both systolic and diastolic function began to decrease.In 4 weeks after the operation,both the the maximum rate of left ventricular isovolumic systolic pressure + dp/dtmax and the maximum rate of left ventricular isovolumic diastolic pressure-dp/dtmax decreased to the lowest levels [(1249.89 ± 95.82) mm Hg/s and(-1316.40 ± 58.31) mm Hg/s,respectively];and then in 6 weeks after the operation,echocardiography showed that the left ventricular short axis fractional shortening FS reached the lowest level [(18.70 ± 3.83)%].Moreover,we found that the FS was highly related with the + dp/dtmax(r=0.864,P<0.001).The hemodynamic examination showed that the diastolic function decreased 2 weeks after the surgery,while echocardiography showed no difference at the time.Conclusions The first 2 weeks after the ligature of the left coronary artery was the early stage of heart failure in the rat models.After this period,either the systolic or the diastolic function begins to decrease.Both echocardiography and hemodynamics can be used to measure the cardiac systolic function of rat,whereas the latter is a better choice for measuring diastolic function.