Preparation of 131Ⅰ-SAP and Evaluation of Its Safety for Further Clinical Application

魏海亮,闫平,张建华,刘萌,康磊,张丽,郭凤琴,张春丽,王荣福
DOI: https://doi.org/10.11748/bjmy.issn.1006-1703.2013.03.018
2013-01-01
Abstract:Objective To prepare a novel imaging agent of 131I-SAP targeting amyloidosis,and evaluate its security for further clinical application.Methods Standard sample of SAP was radiolabeled with 131I by Iodogen method.The labeling efficiency and radiochemical purity of 131I-SAP were calculated by the paper chromatography.The in vitro stability of 131I-SAP under different conditions(4 ℃ and 37℃) were determined at 0,24,48,72 and 96 h respectively.Pyrogen and toxicity tests were also performed.Results The labeling efficiencies of 131I-SAP reached 70.6%,and the radiochemical purity was above 90% at 96 hours.The safety experiments showed that 131I-SAP was free of pyrogen and toxicity.Conclusion 131I-SAP is stable in vitro,and free of pyrogen and toxicity,which may be suitable for further clinical application.
What problem does this paper attempt to address?