Abstract:Objective To evaluate the value of electroencephalogram ( EEG) in the diagnosis of brain death. Methods 88 patients from different hospitals in Zhejiang Province who fulfilled the clinical criteria of brain death were chosen as the subjects to undergo EEC twice in 12 hours, of whom 54 were male and 34 female, aging from 16-82 years old with an average of (43. 6±18. 5) years old. EEC was performed by Belight portable EEC machine made by EB Neuro Company, Italy, according to the international criteria using needle eletrodes. Results 81 cases were showing electrical silence in the two EEC examinations; 6 cases had been recorded to have waves higher than 2μV; in one out of these 6 cases the result was interfered by the artifacts in the initial examination but electrical silence was recorded in this case after 12 h. Conclusion EEC is an important method to assist the diagnosis of brain death for its high sensitivity, only if the instrumental data and testing condition are well controlled.