Fault diagnosis method for a gear pump based on SVDD and distance measure

WANG Tao,LI Ai-hua,WANG Xu-ping,CAI Yan-ping
DOI: https://doi.org/10.3969/j.issn.1000-3835.2013.11.013
2013-01-01
Abstract:A fault diagnosis method for a gear pump based on support vector domain discription(SVDD) and distance measure was put forward.Firstly,vibration signals under various conditions of the gear pump were decomposed with wavelet packet technique to extract energy percentage of each frequency band as feature vectors.Then,a SVDD hypersphere model was trained only using feature vectors under normal condition,and an abnormal condition of gear pump was detected with the definition of the absolute distance measure.Finally,SVDD hypersphere models were trained independently by using feature vectors under various conditions,and various fault conditions of the gear pump were recognized accurately with the definition of the relative distance measure.Experimental results showed that the data dimensions are reduced and the fault information is concentrated efectively by adopting feature extraction with wavelet packet technolog;SVDD fault diagnosis methods based on absolute distance measure and relative distance measure can not only detect abnormal conditions but also distinguish various fault conditions to realize condition monitoring and fault classification.
What problem does this paper attempt to address?