A quicker and visual method for detecting Enterohemorrhagic Escherichia coli O157:H7

LV Heng,ZHANG Jin-hai,GU Hai-tao,WANG Ping,WANG Chang-jun,WANG Yu-bang
DOI: https://doi.org/10.3969/j.issn.1672-271x.2013.04.001
2013-01-01
Abstract:Objective A loop-mediated isothermal amplification(LAMP) assay was developed for rapid visual detection of Enterohemorrhagic Escherichia coli O157∶ H7.Methods A set of six specific primers specific to eight regions of rfbE gene were designed.The reaction was performed in a single tube at 63 ℃ with the addition of hydroxynaphthol blue(HNB) dye prior to amplification.Use Loopamp Realtime Turbidimeter to grope for amplification conditions.The result was determined by the color change of HNB,and the sensitivity and specificty of LAMP method were evaluated.Results The results showed the detection limit of the LAMP assay was 100 copies per tube which was higher than conventional PCR method.The specificity of the LAMP assay was high.Only Enterohemorrhagic Escherichia coli O157: H7 tube changed color.Conclusion These results suggested that the LAMP assay with HNB dye provided a useful tool for the rapid detection of Enterohemorrhagic Escherichia coli O157∶ H7.
What problem does this paper attempt to address?