Frequency and Damping Characteristics of Electromechanical Oscillations in Inter-Connected Power Systems

LI Hongjun,LU Chao
DOI: https://doi.org/10.3321/j.issn:1000-0054.2008.07.006
2008-01-01
Abstract:The frequency and damping characteristics of electromechanical oscillation is ananlyzed with a linearized model based on the equivalent interconnected power grid with a 5 level dynamic generator model.Analyses of the relative block showes that the main factor affecting the frequency is the generator inertia and its distribution in the interconnected network.Lower oscillation frequencies occur in the uniformly distributing sub-networks.The performance of the exciter and the governor worsens the low frequency oscillation and correlates positively with its frequency.It provides more negative damping at lower frequencies.This is the main factor for the poor damping characteristics of interconnected network.Low cost wide-area damping controllers can improve the damping characteristics in interconnected networks.
What problem does this paper attempt to address?