Characteristics of cyanide degradation in A/O/H/O coking wastewater treatment

HUANG Huijing,WEI ChaoHai,WU Chaofei,FENG Chunhua,WU Haizhen,LU Bin
2011-01-01
Abstract:Few studies have been devoted to the real-time analysis of the variation in cyanide concentration in a coking wastewater treatment plant,although this is important for the design of such a plant.This work presented a method to allow high-efficiency removal of cyanide,based on the analysis of the data collected from a real A/O1/H/O2 coking wastewater treatment plant(Shaogang,Guangdong).The results showed that the biodegradation rate of cyanide was much slower than that of phenols present in the biological system,and the degradation rate of metal-complexed cyanide was much slower than that associated with uncomplexed cyanide.The effective removal of carbon and nitrogen in the A/O1/H/O2 biological system was responsible for achieving high-efficiency biodegradation of cyanide.In addition,this work demonstrated that the high-efficiency treatment of coking wastewater could be realized by taking into account the synergetic effect of biodegradation kinetics for different components and the optimization of operating conditions.
What problem does this paper attempt to address?