Whole-body MR Angiography with 32-Receiving Channels and Parallel Imaging Techniques: a Preliminary Clinical Study

LIN Jiang,WANG Jian-hua,YAN Fu-hua,ZENG Meng-su,XU Peng-ju,ZHOU Kang-rong
DOI: https://doi.org/10.3760/j.issn:1005-1201.2006.04.021
2006-01-01
Abstract:Objective To preliminarily evaluate a novel whole-body 3D contrast-enhanced(CE) MR angiography(MRA) technique in the demonstration of various systemic arterial diseases.Methods(Thirty patients) underwent whole-body 3D CE MRA using a 1.5 T MR imager(Magnetom Avanto,Siemens AG) equipped with 32 receiving channels and integrated parallel acquisition techniques(iPAT).The patients included were with clinically documented peripheral arterial occlusive disease (PAOD,n=17),Takayasu arteritis(n=3),polyarteritis nodosa(n=1),Type B dissection(n=4),and thoracic and/or abdominal aneurysm(n=5).68 surface coil elements were employed to encompass the whole body.Four 3D CE MRA stations with each field-of-view of 50 cm were acquired successively through automatic table moving.The gadolinium contrast medium dose was 0.3 mmol/kg and a biphasic injection was employed with 0.15 mmol/kg injected at a rate of 1.3 ml/s and another 0.15 mmol/kg at a rate of 0.6 ml/s.A total scan range of 188 cm,covering the arterial tree from carotid artery to trifurcation vessels,was acquired.Overall image quality of each arterial segment was assessed.The depiction of various systemic arterial diseases was evaluated and compared to other available imaging modalities including X-ray angiography in nine patients,CT angiography in eight patients,and mono-station MRA in one patient.Results Whole-body 3D CE MRA was well tolerated by all patients.It yielded a detailed display of the arterial system with an average room time of 17.4 min.In seven of 17 patients with PAOD,whole-body MRA showed additional vascular narrowing apart from peripheral arterial disease.In four patients with vasculitis,whole-body MRA depicted luminal irregularity,narrowing or occlusion,aneurysm,and collateral circulation involving multiple vascular segments.Whole-body MRA also clearly revealed the severity and extent of dissection and aortic aneurysm.In cases with other available imaging techniques,the demonstration of vascular pathology all agreed except one case of overestimation of stenosis by whole body MRA.Conclusion Our results showed this 32-receiving-channel MR system with surface coil technology allowed a quick and easy-to-perform whole-body MRA.It was very valuable for a comprehensive evaluation of vascular involvement of various systemic arterial diseases.
What problem does this paper attempt to address?