Experimental Study on Post Combustion Characteristics of the Imported 300 MW Circulating Fluidized Bed Boiler

Jiayi Lu,LU Xiaofeng,WANG Hu,WANG Quanhai,Honghao He,GAN Lu,ZHAO Peng,TANG Xiuneng,LEI Xiujian,ZHANG Wenqing,CHEN Jianbin
2012-01-01
Abstract:Gas concentrations of the external circulation loop in the imported 300 MW circulating fluidized bed(CFB) boiler were measured by self-made probes to investigate the combustion characteristics of the cyclones and external heat exchangers(EHEs).Results implied that there was significant post combustion phenomenon in the boiler's external circulation loop,and most of the combustion was from the cyclones.The flue gas temperature at the cyclone outlet could be 135 ℃ higher than that at the cyclone inlet.The ratio of the O2 consumption in the cyclone to that of the whole combustion process in the boiler could be as high as 12%.With regard to the EHEs,the inside combustion phenomenon was not as severe as that in the cyclones.Obvious differences of gas concentrations were observed at the outlet between those EHEs with different functions.The O2 consumption of the furnace temperature adjusting EHEs could be twice that of the reheat steam temperature adjusting EHEs.These experimental results can provide information for the design of mew CFB boilers.