Abstract:According to the actual instance of Shajiao C Power Station in Guangdong province, implementing mill condition-based maintenance is better than break-down maintenance and time-based maintenance, aimed at HP983 medium speed mill of 660MW Unit milling system, a whole condition-based maintenance theoretical scheme is put forward, and mill condition-based maintenance software aided system is produced and shown, after condition-based maintenance, mill maintenance expense is reduced greatly ,and mill reliability and use efficiency is enhanced.