Influence of Congenital Hypothyroidism on Cardiac Function and Electrocardiography of Neonates

毛姗姗,邹朝春
DOI: https://doi.org/10.3969/j.issn.1674-6449.2010.04.004
2010-01-01
Abstract:Objective To investigate the changes of left and right ventricular function and electrocardiography(ECG) in neonates with congenital hypothyroidism. Methods Fifty full-term neonates with congenital hypothyroidism as well as 35 normal neonates underwent conventional M-mode echocardiography,pulsed-wave Doppler echocardiography(PWD),tissue Doppler Echocardiography(TDE) and ECG.M-mode echocardiography was used to examine left ventricular fractional shortening(LVFS),left ventricular ejection fraction(LVEF),left atrial diameter(LA),and aortic diameter(AO),and the LA/AO ratio was calculated.PWD was used to examine peak early diastolic mitral and tricuspid inflow velocity(E),peak late diastolic mitral and tricuspid inflow velocity(A),and the E/A ratio was calculated.TDE was used to examine peak systolic transmitral and transtricuspid annular velocity(Sa),peak early transmitral and transtricuspid annular velocity(Ea),peak late transmitral and transtricuspid annular velocity(Aa),and the Ea/Aa ratio was calculated.ECG included heart rate(HR),PR interval(PR),QRS time(QRS),QRS axis in the frontal plane(QRSa),QT time(QT),and corrected QT time(QTc). Results M-mode echocardiography showed that LVEF and LVFS were significantly lower in congenital hypothyroidism neonates,whereas LA,AO,and LA/AO did not show statistically significant differences.PWD showed that congenital hypothyroidism neonates had significantly lower E and E/A of the mitral and tricuspid valve.TDE showed that congenital hypothyroidism neonates had significantly lower Sa,Ea and Ea/Aa of both left and right ventricles.However,Aa of left and right ventricle did not differ significantly.HR in congenital hypothyroidism group was significantly low compared with the normal control group,and PR and QT in congenital hypothyroidism group were significantly longer than in the control group.No statistical differences of QRS,QRSa,and QTc were noted between two groups. Conclusion Neonates with congenital hypothyroidism are associated with right ventricular subclinical systolic and diastolic dysfunction in addition to left ventricular dysfunction.Congenital hypothyroidism has predominant effect on pacemaker cells of sinus node in neonates,which result in changes of autorhythmicity,while some other electrophysiologic effects such as cardiac action potential or atrioventricular conduction have not yet been affected.
What problem does this paper attempt to address?