Effect of different methods of anterior cervical surgery on postoperative instant stability

ZHU Zhenqi,XIAO Shipeng,LIU Haiying
DOI: https://doi.org/10.3969/j.issn.1672-2957.2007.04.012
2007-01-01
Journal of Spinal Surgery
Abstract:Objective To evaluate the biomechanical stability of the cervical spine with single-level discectomy followed by cervical vertebra fusion with Solis cage and anterior plate in goat cervical models. Methods Eight goat cervical specimens from C2-7 were used to establish models in order as below: C4,5 discectomy, C4 to C5 fusion with Solis cage, intervertebra graft and fusion between C4 to C5 and anterior plating stabilization. Non-destructive test was used to assess the loading and translation of the cervical spine in flexion, extension, side bending. Mean value of displacement/load was calculated and compared. Results It showed that the flexion motion after C4,5 discectomy was increased by 40%(P<0.05),The extension motion was increased by 31%(P<0.05),And the side bending was increased by 32%(P<0.05).The three dimensional movements were decreased obviously following cervical vertebra fusion with Solis cage and anterior plate, which increased the stability of the cervical spine when moving in the three direction. Conclusion Both intervertebra graft combined with anterior plate interfixation and intervertebra Solis cage inplacement can obtain good stability. Due to less postoperative complication of the latter, the cage inplacement can replace the anterior plate stabilization.
What problem does this paper attempt to address?