Detection of Caffeine in Xinyangmaojian Tea by an Electronic Nose
ZHANG Hongmei,WANG Jun,YU Yongchang,GAO Xiankun,HUA Hengming,HE Yujing
DOI: https://doi.org/10.3969/j.issn.1004-1699.2011.08.028
2011-01-01
Abstract:Three different grades of Xinyangmaojian tea were detected by an electronic nose system.The optimization of a gas sensor array consisting of four gas sensors was selected by loading analysis and correlation analysis.Principle component analysis of the data provided by the electronic nose completely distinguished all the tea samples.The principle component regression(PCR),multiple linear regression(MLR),and quadratic polynomial step regression(QPSR)models of the caffeine content of Xinyangmaojian tea were created based on the optimization of gas sensor array and were validated by a prediction set.The correlation coefficient,standard error prediction,and average percent error between the predicted content and the measured content of caffeine of these three models were 0.66,0.32,and 3.42%;0.80,0.19,and 2.8%;and 0.94,0.19,and 2.3%,respectively.The QPSR model was better than the PCR and MLR models.The results show that the electronic nose system can detect the caffeine content of Xinyangmaojian tea.