Design and Realization of Dynamic Test System Used for IMU
ZHAO Bin,ZHOU Jun,LU Jun-jie,LU Xiao-dong
DOI: https://doi.org/10.3969/j.issn.1000-8829.2011.04.004
2011-01-01
Abstract:The conventional IMU dynamic test system method has two shortcomings,no uniform time marker and low efficiency.To resolve these questions,a dynamic test system based on the xPC kernel is designed.As for this test system,firstly,the general design and the flow design are finished.Then the key techniques are studied,which mainly includes the design of the test control platform software and the realization of the parameter download,the design of the IMU communication module,the design of the three axis table data communication module,the design of the software used for the read-time data save and display,and so on.The test system can ensure that the data acquisition is finished in the same read-time clock.Long term test indicates that the sample frequency of this test system can achieve 1 kHz without error in 10 minutes,so it is proved the validity of the system.