Correlation Between Blood Glucose Indexes Generated by the Flash Glucose Monitoring System and Diabetic Vascular Complications
Xia Sheng,Ting Li,Yi Hu,Cheng-Shun Xiong,Ling Hu
DOI: https://doi.org/10.2147/DMSO.S418224
2023-08-17
Abstract:Xia Sheng, Ting Li, Yi Hu, Cheng-Shun Xiong, Ling Hu Department of Endocrine, The First Hospital of NanChang City, Nanchang, Jiangxi, 330008, People's Republic of China Correspondence: Ling Hu, Email Objective: To discuss the relationship between time in range (TIR) which is deprived of the FGMS and the risk of diabetic vascular complications and to provide a theoretical foundation for the clinical application of TIR and other FGMS-deprived indexes. Methods: Patients with T2DM who wore the FGMS sensor continuously were enrolled. Relevant indexes such as TIR, time below range (TBR), time above range (TAR), a standard deviation of blood glucose (SDBG), coefficient of variation of blood glucose (CV), and mean amplitude of glycemic excursion (MAGE) generated by the FGMS were recorded, and the risk of diabetic vascular complications were followed up for one year. The TIR was measured by continuous glucose monitoring at baseline, and patients were grouped according to TIR every 20%. Finally, the Cox proportional hazards regression model was used to estimate the association of different levels of TIR with different rates of diabetic vascular complications. Results: TIR was negatively correlated with HbA1C, CV, SDBG, and amplitude of glycemic excursion (MV), wherein, the lower the TIR, the higher the HbA1C, CV, SDBG, and MV. TIR in the diabetic microvascular complication was significantly lower than that in the non-microvascular complication group, and the difference was statistically significant. TIR 10.0 mmol/L) and time below range (TBR) (<3.9 mmol/L) should be analyzed in blood glucose assessment. 4 TIR combined with indexes such as TAR and TBR can better reflect and help control the changes in blood glucose of individuals. The application value of the glucose index derived from this emerging CGM technology in the Chinese population remains unexplored due to the lack of clinical experience with FGMS, as it has not been in the market for a long time. 5 In addition, correlation studies between TIR and diabetes-related chronic complications are scarce. This study aims to examine the relationship between blood glucose-related indexes automatically generated by the FGMS and diabetes-related chronic complications to provide evidence for TIR which is a reference index for clinical blood glucose regulation and a predictor of the risk for diabetic complications in multiple aspects. A total of 545 patients with T2DM who wore the flash glucose monitoring sensor (for 7–14 days) during their stay at the hospital between October 2020 and October 2021 were enrolled, and a retrospective study was conducted. Clinical data were obtained from the clinical electronic medical record database and the FGM companion software. This s -Abstract Truncated-
endocrinology & metabolism