Abstract:As a result of pollution in the present water sources, cities have been forced to utilize cleaner water sources. There are few reports regarding the potential shift of bacterial community structure driven by water source switching, especially that of corrosion-related bacteria. Three types of finished water were used for simulation, the polluted source water from the Qiantang and Dongtiaoxi Rivers (China) was replaced by cleaner water from Qiandao Lake (China). Here, we discussed the transition effects through three simulated reactors. The bacterial characteristics were identified using the high-throughput sequencing and heterotrophic plate count method. It was observed that the level of culturable bacteria declined by 2–3 orders of magnitude after water source switching. The bacterial community released from the pipeline reactor was significantly different under different finished water, and it exhibited large variation at the genus level. <i>Porphyrobacter</i> (58.2%) and <i>Phreatobacter</i> (14.5%) clearly replaced <i>Novosphingobium, Aquabacterium</i>, and <i>Cupriavidus</i> as new dominant genera in system A, which could be attributed to the lower carbon and nitrogen content of the new water source. Although corrosion-inhibiting bacteria decreased after switching, they still maintained dominant in three reactors (6.6%, 15.9%, and 19.7%). Furthermore, potential opportunistic pathogens such as <i>Sphingomonas</i> were detected. Our study shows that after transition to a high quality water source, the total culturable bacteria released was in a downtrend, which leads to a great reduction in the risk of bacterial leakage in the produced drinking water.
environmental sciences,engineering, environmental
What problem does this paper attempt to address?
This paper attempts to address the issue of changes in bacterial community structure and corrosion-related bacteria in drinking water pipeline systems due to water source switching. Specifically, the study focuses on how the bacterial communities in drinking water pipeline systems change when a city switches from more polluted water sources (such as the Qiantang River and Dongtiaoxi River) to cleaner water sources (such as Qiandao Lake), especially those bacteria related to corrosion. The research explores the impact of different water qualities on the bacterial communities within the pipelines through simulated experiments and evaluates the effect of these changes on the biological safety of drinking water. The results indicate that after switching to a higher quality water source, the number of culturable bacteria significantly decreases, thereby greatly reducing the risk of bacterial leakage and improving the safety of drinking water.