Sulfate removal mechanism by internal circulation iron-carbon micro-electrolysis

Yanhe Han,Chuantao Wu,Xiaolu Fu,Zhimin Su,Meili Liu
DOI: https://doi.org/10.1016/j.seppur.2021.119762
IF: 8.6
2021-12-01
Separation and Purification Technology
Abstract:Internal circulation iron-carbon micro-electrolysis (ICE) was used to treat sulfate in wastewater. The influences of the reaction time, aeration rate, pH, iron-carbon ratio, and the initial sulfate concentration on sulfate removal by ICE were investigated. The maximum sulfate removal efficiency was 76.6% under the following conditions: reaction time = 120 min, aeration rate = 0.5 m3/h, pH = 2, iron-carbon ratio = 1:1, and initial sulfate concentration = 500 mg/L. Scanning electron microscopy, energy-dispersive spectrometry, X-ray photoelectron spectroscopy, X-ray diffraction, and Raman spectroscopy analyses were performed to study the sulfate removal mechanism. The results showed that sulfate was mainly removed by two mechanisms: 1) sulfate may initially be reduced to SO3 2-, and then to S2-, which combines with H+ and Fe2+ to form H2S and FeS, which can be removed; 2) sulfate can be removed by flocculation and precipitation of Fe(OH)2 and Fe(OH)3. Therefore, the ICE process can be used as an effective method to remove sulfate from wastewater.
engineering, chemical
What problem does this paper attempt to address?