Attenuation of shading loss using a novel solar array reconfigured topology under partial shading conditions

Vijay Laxmi Mishra,Yogesh K. Chauhan,K.S. Verma
DOI: https://doi.org/10.1016/j.solener.2024.112552
IF: 7.188
2024-05-04
Solar Energy
Abstract:Partial shading conditions (PSC) degrade the maximum power production from the solar arrays. It generates shading losses which is dependent on the quantity of shade spread out on the solar array. This research proposes a novel Grecian square reconfiguration (NGR) for a 4 × 4 solar array to prevent shading issues. This novel technique is extensively compared with other benchmark solar models like total-cross-tied (TCT), kendoku (KDT), odd–even (OER), and skyscraper reconfigurations (SSR). The effectiveness of the proposed NGR is validated under four complex shadings. A thorough comparison of the proposed NGR is made based on several performance parameters like global power (GP), shading loss (SL), fill factor (FF), efficiency (Ƞ), power gain (PG), and execution ratio (ER). The experimental outcome validates the MATLAB/Simulink results, denoting the excellent performance of the proposed NGR over the existing TCT, KDT, OER, and SSR respectively. The proposed NGR magnifies the global power by 30.36%, 9.53%, 5.95%, and 21.38% under corner shading against TCT, KDT, OER, and SSR schemes. Also, under oblique shading, the shading loss is reduced by 72.04%, 91.91%, 37.04%, and 44.68% by the proposed NGR against TCT, KDT, OER, and SSR schemes. The outstanding performance of the proposed NGR against the TCT, KDT, OER, and SSR schemes under the considered shadings depicts its supremacy in handling shading issues effectively.
energy & fuels
What problem does this paper attempt to address?