The Reliability of Carotid Artery Doppler Ultrasonography Indices in Predicting Fluid Responsiveness during Surgery for Geriatric Patients: A Prospective, Observational Study

Beliz Bilgili,Ayten Saracoglu,Kemal T. Saracoglu,Pawel Ratajczyk,Alper Kararmaz
DOI: https://doi.org/10.3390/healthcare12070783
2024-04-04
Health Care
Abstract:Background: The reliability of determining fluid responsiveness during surgery in geriatric patients is challenging. Our primary outcome was to determine the reliability of Corrected Flow Time (FTc) in predicting fluid responsiveness. Methods: Elderly patients undergoing major surgery under general anesthesia were included. Measurements of common carotid artery diameter, velocity time integral, and systolic flow time (FT) were performed before and after a fluid challenge. FTc and carotid blood flow (CBF) were subsequently calculated. Results: The median change in carotid diameter was significantly higher in the fluid-responder (R) compared to the non-responder (NR) (6.51% vs. 0.65%, p = 0.049). The median change in CBF was notably higher in R compared to NR (30.04% vs. 9.72%, p = 0.024). Prior to the fluid challenge, systolic FT was significantly shorter in R than NR (285 ms vs. 315 ms, p = 0.027), but after the fluid challenge, these measurements became comparable among the groups. The change in systolic FT was higher in R (15.38% vs. 7.49%, p = 0.027). FTc and the change in FTc exhibited similarities among the groups at all study time points. Receiver operating characteristic analysis demonstrated an area under the curve of 0.682 (95% CI: 0.509–0.855, p = 0.039) for carotid diameter, 0.710 (95% CI: 0.547–0.872, p = 0.011) for CBF, 0.706 (95% CI: 0.540–0.872, p = 0.015) for systolic FT, and 0.580 (95% CI = 0.389–0.770, p = 0.413) for FTc. Conclusions: In geriatric patients, potential endothelial changes in the carotid artery may influence the dynamic markers of fluid responsiveness. Despite the demonstrated effectiveness of FTc in predicting fluid responsiveness in the general population, this study underscores the limited reliability of carotid Doppler ultrasonography indices for prediction in a geriatric patient population.
health care sciences & services,health policy & services
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is to evaluate the reliability of carotid Doppler ultrasound indicators in predicting fluid responsiveness during surgery in elderly patients. Specifically, the focus of the study is to determine whether the Corrected Flow Time (FTc) can effectively predict the fluid responsiveness of elderly patients. In addition, the study also aims to identify the critical value of FTc and the predictive ability of other carotid Doppler ultrasound indicators (such as carotid blood flow and systolic flow time) in predicting fluid responsiveness. ### Research Background With the growth of the elderly population, the frequency of elderly patients undergoing surgery is also increasing. These patients usually show problems such as left ventricular diastolic dysfunction, decreased vascular reactivity, and reduced venous compliance. As people age, vascular endothelial function gradually declines, leading to decreased vascular dilation ability, impaired response to vasoactive substances, and enhanced vasoconstriction. These changes will affect blood flow regulation, reduce tissue perfusion, and increase the risk of cardiovascular diseases, such as hypertension and atherosclerosis. Therefore, it is particularly important to accurately assess the intravascular fluid status of elderly patients and their response to fluid intervention during the surgical process. ### Research Objectives 1. **Primary Objective**: Determine the reliability of the Corrected Flow Time (FTc) in predicting fluid responsiveness during surgery in elderly patients. 2. **Secondary Objective**: Identify the critical value of FTc and the predictive ability of other carotid Doppler ultrasound indicators (such as carotid blood flow and systolic flow time) in predicting fluid responsiveness. ### Methods - **Research Design**: Prospective observational study. - **Research Subjects**: Patients aged 65 and above, with ASA grades I - III, undergoing major surgery and requiring invasive arterial monitoring. - **Exclusion Criteria**: Patients with severe kidney disease and cardiovascular diseases, those who have fasted for more than 8 hours, or those with sepsis. - **Anesthesia Induction**: General anesthesia induction was performed by intravenous injection of propofol, fentanyl, and rocuronium using conventional monitoring equipment. - **Minimally Invasive Hemodynamic Monitoring**: Monitored using the Most Care® device. - **Carotid Ultrasound Examination**: Measure the carotid artery diameter, velocity - time integral (VTI), systolic flow time (FT), and Corrected Flow Time (FTc). - **Sample Size Calculation**: Based on previous studies, assuming a fluid responsiveness/non - responsiveness ratio of 1, the sample size was calculated to be 40 cases. With an expected 10% data loss, 44 patients were finally included. - **Statistical Analysis**: Statistical analysis was performed using R software. The Shapiro - Wilk test was used to assess the normality of the data, the Mann - Whitney U test and Wilcoxon signed - rank test were used for inter - group and intra - group comparisons, and the ROC curve analysis was used for predictive values. ### Results - **Baseline Characteristics**: 40 patients were divided into a non - responsive group (22 cases) and a responsive group (18 cases), and there were no significant differences in the baseline characteristics between the two groups. - **Blood Pressure and Heart Rate**: The mean arterial pressure in the non - responsive group before the fluid challenge was significantly higher than that in the responsive group, but the difference between the two groups after the fluid challenge was not clinically significant. - **Carotid Artery Diameter**: The carotid artery diameter in the responsive group increased significantly after the fluid challenge. - **Carotid Blood Flow**: The change in carotid blood flow in the responsive group was significantly greater than that in the non - responsive group. - **Systolic Flow Time**: The systolic flow time in the responsive group before the fluid challenge was significantly shorter than that in the non - responsive group, but the difference between the two groups disappeared after the fluid challenge. - **Corrected Flow Time**: After the fluid challenge, the FTc values in both groups increased significantly, but the difference between the groups was not statistically significant. ### Conclusion Although FTc has been proven to be effective in predicting fluid responsiveness in the general population, in elderly patients, due to potential endothelial changes, the reliability of carotid Doppler ultrasound indicators in predicting fluid responsiveness is limited. This indicates that in elderly patients, further exploration of other more reliable assessment methods is required.