Satellite laser ranging to Galileo satellites: symmetry conditions and improved normal point formation strategies

Michael A. Steindorfer,Franz Koidl,Georg Kirchner,Peiyuan Wang,Florian Dilssner,Erik Schoenemann,Aaron Strangfeld,Francisco Gonzalez
DOI: https://doi.org/10.1007/s10291-024-01615-9
2024-02-17
GPS Solutions
Abstract:High-precision satellite laser ranging measurements to Galileo retroreflector panels are analyzed to determine the angle of incidence of the laser beam based on specific orientations of the panel with respect to the observing station. During the measurements, the panel aligns with respect to the observing station in such a way that multiple retroreflectors appear at the same range, forming regions of increased data density—separated by a few millimeters. First, measurements to a spare IOV-type retroreflector mounted on an astronomical mount at a remote location 32 km away from the Graz laser ranging station are performed. In addition, more than 100 symmetry passes to Galileo satellites in orbit have been measured. Two novel techniques are described to form laser ranging normal points with improved precision compared to traditional methods. An individual normal point can be formed for each set of retroreflectors at a constant range. The central normal point was shown to be up to 4 mm more accurate when compared with a precise orbit solution. Similar offsets are determined by applying a pattern correlation technique comparing simulated with measured data, and the first method is verified. Irregular reflection patterns of Galileo FOC panels indicate accumulated far-field diffraction patterns resulting from non-uniform retroreflector distributions.
remote sensing
What problem does this paper attempt to address?
### Problems Addressed by the Paper This paper primarily explores how to improve the measurement accuracy of Galileo satellites using Satellite Laser Ranging (SLR) technology. Specifically, the researchers analyzed high-precision laser ranging data and determined the laser beam's incidence angle based on the direction of specific reflectors relative to the observation station. The study proposes two new technical methods to form normal points in laser ranging, achieving higher accuracy than traditional methods. #### Main Research Content: 1. **Laser Ranging under Symmetrical Conditions**: The researchers created high-density data regions by ensuring multiple corner reflectors appear at the same distance under specific symmetrical conditions. This symmetry can be achieved by adjusting the satellite's attitude. 2. **New Normal Point Formation Strategies**: Two methods were proposed: the peak method and the pattern correlation method. The peak method forms normal points when multiple corner reflectors align at the same distance based on the panel's symmetrical conditions. The pattern correlation method determines the panel's center position and forms normal points by comparing simulated data with actual observation data. 3. **Experimental Validation**: To verify the effectiveness of these new methods, the researchers conducted numerous experiments, including measurements of a spare Galileo IOV-type corner reflector panel mounted on an astronomical telescope and over 100 symmetrical condition measurements of Galileo satellites in orbit. 4. **Data Analysis**: Through the analysis of experimental data, the researchers found that the normal points formed using the new methods improved accuracy by up to 4 millimeters compared to traditional precise orbit determination solutions. Additionally, the pattern correlation method further validated the effectiveness of the peak method. In summary, this paper aims to improve the ranging accuracy of Galileo satellites by enhancing laser ranging techniques, thereby better serving the construction of the Earth reference frame and other scientific applications.