Analysis of lipopolysaccharides by coupling microscale solid-phase extraction with capillary electrophoresis-laser induced fluorescence

Rachel Rui Xia Lim,Fun Man Fung,Hua-Tao Feng,Sam Fong Yau Li
DOI: https://doi.org/10.1016/j.microc.2020.105771
IF: 5.304
2021-02-01
Microchemical Journal
Abstract:<p>Lipopolysaccharides (LPS), also known as endotoxins, can be released into the environment when the bacteria's cell wall breaks apart, which induces inflammatory responses in humans at amounts of 1–10 ng kg<sup>−1</sup>. This paper reports on the development and optimization of a novel analytical method for the analysis of LPS based on the coupled use of a laboratory–made microscale solid-phase extraction (μSPE) device for the purification and enrichment of LPS before fluorescent dye derivatization and lastly capillary electrophoresis with laser-induced fluorescence (CE-LIF) for separation and detection. In this work, the limits of detection and quantification of <em>Klebsiella pneumoniae</em> (KP)-LPS were found to reach 1.32 ng mL<sup>−1</sup> and 4.39 ng mL<sup>−1</sup>, respectively with a linear dynamic range of 0.125–0.625 mg L<sup>−1</sup> and a relative standard deviation of 0.9% in migration time. Scanning electron microscopy analysis clearly supports the successful entrapment of KP-LPS within the sorbent before elution. In contrast to other LPS extraction methods, the optimized μSPE-based method coupled with CE-LIF provides the following advantages: small sample amount for sensitive and selective detection in CE-LIF (μSPE preconcentration factor of 23 times), reduced volumes of organic solvents used (175–225 µL), high recovery rate of 98%, as well as portability for on-site extraction and quantification of analytes. The method was successfully applied in the analysis of three types of real water samples (i.e. deionized water, secondary effluent and raw sewage). Raw sewage was found to contain the highest KP-LPS amount of 12.5 ng mL<sup>−1</sup> followed by secondary effluent of 7.3 ng mL<sup>−1</sup>.</p>
chemistry, analytical
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to develop a new type of analysis method for the detection of lipopolysaccharide (LPS, also known as endotoxin). Specifically, this study aims to achieve highly efficient purification, enrichment, and sensitive detection of LPS by combining a laboratory - made micro - scale solid - phase extraction (μSPE) device with capillary electrophoresis - laser - induced fluorescence (CE - LIF) technology. The following are the key problems that the paper attempts to solve: 1. **Improve the sensitivity and selectivity of LPS detection**: Existing LPS detection methods, such as the LAL test, although highly sensitive, have problems such as high cost and unstable results due to the influence of multiple factors. In addition, methods such as GC/MS can quantify LPS, but they are complex to operate, time - consuming, and costly. Therefore, a more economical, rapid, and sensitive method for detecting LPS is required. 2. **Reduce the sample demand and the amount of organic solvents used**: Traditional LPS extraction methods usually require a large amount of samples and organic solvents, which not only increase the experimental cost but also may cause environmental pollution. Through optimizing the μSPE method, this study has achieved highly efficient enrichment with a small sample amount and at the same time reduced the amount of organic solvents used. 3. **Improve the recovery rate and portability**: Traditional LPS extraction methods often have a low recovery rate, and the equipment is bulky and not convenient for on - site detection. Through optimizing the μSPE - CE - LIF combined technology, this study has achieved a recovery rate as high as 98%, and the equipment is portable and suitable for on - site detection. 4. **Apply to the detection of LPS in actual water samples**: This study has not only verified the effectiveness of the method in standard solutions but also applied it to the detection of LPS in actual water samples (deionized water, secondary effluent, and raw sewage), proving the feasibility and reliability of this method in practical applications. In summary, the main objective of this paper is to develop an efficient, sensitive, economical, and portable LPS detection method to overcome the limitations of existing methods and provide strong support for environmental monitoring and public health.