Low-impedance tissue-device interface using homogeneously conductive hydrogels chemically bonded to stretchable bioelectronics

Yoonsoo Shin,Hyun Su Lee,Yongseok Joseph Hong,Sung-Hyuk Sunwoo,Ok Kyu Park,Sueng Hong Choi,Dae-Hyeong Kim,Sangkyu Lee
DOI: https://doi.org/10.1126/sciadv.adi7724
IF: 13.6
2024-03-21
Science Advances
Abstract:Stretchable bioelectronics has notably contributed to the advancement of continuous health monitoring and point-of-care type health care. However, microscale nonconformal contact and locally dehydrated interface limit performance, especially in dynamic environments. Therefore, hydrogels can be a promising interfacial material for the stretchable bioelectronics due to their unique advantages including tissue-like softness, water-rich property, and biocompatibility. However, there are still practical challenges in terms of their electrical performance, material homogeneity, and monolithic integration with stretchable devices. Here, we report the synthesis of a homogeneously conductive polyacrylamide hydrogel with an exceptionally low impedance (~21 ohms) and a reasonably high conductivity (~24 S/cm) by incorporating polyaniline-decorated poly(3,4-ethylenedioxythiophene:polystyrene). We also establish robust adhesion (interfacial toughness: ~296.7 J/m 2 ) and reliable integration between the conductive hydrogel and the stretchable device through on-device polymerization as well as covalent and hydrogen bonding. These strategies enable the fabrication of a stretchable multichannel sensor array for the high-quality on-skin impedance and pH measurements under in vitro and in vivo circumstances.
multidisciplinary sciences
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to achieve a low - impedance tissue - device interface in stretchable bioelectronics. Specifically, the main challenges faced by researchers include: 1. **Micro - scale non - conformal contact**: Most stretchable devices use high - modulus materials (such as polymer films, metal and oxide films). These materials are prone to non - conformal contact on rough organ surfaces, resulting in high contact impedance in the contact area, especially more obvious in dynamic environments. This non - conformal contact and high - impedance interface significantly limit the performance of stretchable bioelectronics. 2. **Dry interface**: The locally dehydrated interface can also affect the performance of the device, especially during long - term use or in dynamic environments. 3. **Electrical properties, material uniformity and monolithic integration**: Although hydrogels are widely regarded as ideal interface materials because of their tissue - like softness, water - rich characteristics and biocompatibility, there are still practical challenges in terms of electrical properties, material uniformity and monolithic integration with stretchable devices. For example, a large amount of conductive materials usually need to be added to the hydrogel to improve conductivity, but this may lead to non - uniform materials and it is difficult to achieve reliable integration with stretchable devices. To overcome these challenges, researchers have proposed two main strategies: 1. **Synthesis of uniformly conductive polyacrylamide hydrogels**: By incorporating a low concentration of poly(3,4 - ethylenedioxythiophene: polystyrene sulfonate) (PEDOT:PSS) into polyacrylamide (PAAm) hydrogels and further decorating with polyaniline (PANi) on it, a uniformly conductive hydrogel with extremely low impedance (about 21 ohms) and relatively high conductivity (about 24 S/cm) is prepared. 2. **Establish reliable adhesion and monolithic integration**: By in - situ polymerizing the hydrogel on the device and achieving strong adhesion between the hydrogel and the stretchable device through covalent bonds and hydrogen bonds, reliable performance can be ensured even under dynamic mechanical deformation. These strategies enable researchers to develop a soft, low - impedance, highly conductive hydrogel that can seamlessly contact the skin or target tissue, thereby achieving high - quality impedance and pH value measurements under in - vitro and in - vivo conditions.