Construction of a highly sensitive signal electrochemical sensor based on self-assembled cobalt oxide-hydroxylated single-walled carbon nanotubes composite for detection of dopamine in bovine serum samples

Jiao Zou,Jin-Feng Guan,Guo-Qing Zhao,Xin-Yu Jiang,Yi-Ping Liu,Jin-Gang Yu,Wen-Jie Li
DOI: https://doi.org/10.1016/j.jece.2021.105831
IF: 7.7
2021-10-01
Journal of Environmental Chemical Engineering
Abstract:<p>A novel electrochemical sensor based cobalt oxide nanoparticles and hydroxylated single-walled carbon nanotubes composite (Co<sub>3</sub>O<sub>4</sub>/SWCNTs-OH) for the highly sensitive detection of dopamine (DA) was successfully developed in present work. Spinel Co<sub>3</sub>O<sub>4</sub> crystals were synthesized by a facile hydrothermal process without high-temperature calcination procedure, and then self-assembled with SWCNTs-OH. The obtained Co<sub>3</sub>O<sub>4</sub>/SWCNTs-OH composite possesses large surface area and cross-linked structure. The morphology, compositions, surface functional groups, and crystal structure of Co<sub>3</sub>O<sub>4</sub>/SWCNTs-OH composite were characterized by Field emission scanning electron microscopy (FE-SEM), Fourier transform infrared spectroscopy (FT-IR) and X-ray diffraction (XRD). The electrochemical properties and catalytic performance of prepared sensor (Co<sub>3</sub>O<sub>4</sub>/SWCNTs-OH/GCE) were studied by electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and differential pulse voltammetry (DPV). These results showed that Co<sub>3</sub>O<sub>4</sub>/SWCNTs-OH/GCE exhibited excellent electrocatalytic performance in terms of DA oxidation peak potential and current density in comparison with bare GCE, Co<sub>3</sub>O<sub>4</sub>/GCE and SWCNTs-OH/GCE. Under optimum conditions, Co<sub>3</sub>O<sub>4</sub>/SWCNTs-OH/GCE exhibited a good linear relationship between DA concentrations and current responses in the range 1–100 μM. Low detection limit of 0.08 μM (signal-to-noise ratio of 3, S/N = 3) and high sensitivity of 1.427 μA μM<sup>−1</sup> could be observed at Co<sub>3</sub>O<sub>4</sub>/SWCNTs-OH/GCE. In addition, the quantitative detection of DA in bovine serum samples at Co<sub>3</sub>O<sub>4</sub>/SWCNTs-OH/GCE showed satisfactory recoveries (93.68–105.47%) and low relative standard deviation (<em>RSD</em>) (3.02–5.83%). The outstanding sensitivity, good selectivity and reproducibility of Co<sub>3</sub>O<sub>4</sub>/SWCNTs-OH/GCE might be attributed to the synergistic effects between Co<sub>3</sub>O<sub>4</sub> and SWCNTs-OH. The fabricated Co<sub>3</sub>O<sub>4</sub>/SWCNTs-OH composite might be used as a promising catalyst for the practical electrochemical detection of DA.</p>
engineering, chemical, environmental
What problem does this paper attempt to address?