Influence of electron cyclotron current drive on the transition between normal sawteeth and the stationary state

Wen Jin Chen,Wei Zhang,Zhiwei Ma,Hanxiao Zhang,Xin Wang
DOI: https://doi.org/10.1088/1361-6587/ad1ebf
IF: 2.532
2024-01-17
Plasma Physics and Controlled Fusion
Abstract:The transition between normal sawteeth and a sawtooth-free stationary state after electron cyclotron current drive (ECCD) deposition has been numerically investigated by the CLT code. The periods of normal sawteeth decrease if co-ECCD deposits inside the initial q=1 surface and increase when co-ECCD deposits outside the q=1 surface. When co-ECCD deposits in the vicinity of the q=1 surface, the normal sawteeth can be converted into a stationary state, during which sawteeth are completely prevented. The stationary state can also be converted into normal sawteeth if co-ECCD is injected just outside the q=1 surface. The mechanism of the transition between normal sawteeth and sawtooth-free stationary states is then discussed.
physics, fluids & plasmas
What problem does this paper attempt to address?