High-flux recovery of aromatic compounds from tobacco extract using an MCM-41/PDMS hybrid membrane

Ruoxin Hu,Zhenbo Cai,Lijun Ji,Yanyang Wu,Xiaohua Ma
DOI: https://doi.org/10.1016/j.seppur.2024.126822
IF: 8.6
2024-02-24
Separation and Purification Technology
Abstract:Recovery of valuable aromatic compounds from tobacco waste is important, and efficient separation methods remain highly demanding. This work proposed a hybrid PDMS membrane for high flux aromatic compounds recovery. MCM-41, a silicone-based molecular sieve, was selected to fabricate the membrane to improve the pervaporation performance. The prepared MCM-41/PDMS membrane was investigated in model aqueous solution at different concentrations and temperatures. The optimal pervaporation fluxes of the MCM-41/PDMS membrane achieved 0.95 g/(m 2 ·h), 0.51 g/(m 2 ·h), and 0.26 g/(m 2 ·h) for 2-phenylethanol, β-ionone, and dihydroactinidiolide, respectively, exhibiting superior performance to the PDMS membrane. Moreover, the long-term stability of the hybrid membrane was examined with practical tobacco extract. The average fluxes were 41.20 mg/(m 2 ·h), 20.57 mg/(m 2 ·h), and 9.73 mg/(m 2 ·h), respectively. The hybrid PDMS membrane in this study, with high permeate flux and selectivity, is promising for recovery of aromatic compounds particularly from tobacco waste.
engineering, chemical
What problem does this paper attempt to address?