Nonequilibrium Ablation of Phenolic Impregnated Carbon Ablator

T. Gokcen,F. Milos,Yih-Kang Chen
DOI: https://doi.org/10.2514/1.A32298
2010-01-04
Abstract:Phenolic Impregnated Carbon Ablator is the forebody heatshield material for the Mars Science Laboratory, the Stardust sample-return capsule, and the SpaceX Dragon vehicle. In previous work an equilibrium ablation and thermal response model was developed. Model predictions were compared with data from many stagnation arcjet tests conducted over a range of stagnation heat flux and pressure from 107 W/cm 2 at 2.3 kPa to 1100 W/cm 2 at 84 kPa. In general, model predictions compared well with the data for surface recession, surface temperature, in-depth temperature at multiple thermocouples, and char depth. The uncertainty of the recession predictions was greatest for test conditions with low heat flux or low pressure. Additional testing has been performed at conditions down to 40 W/cm 2 and 1.6 kPa. The new test data suggest that nonequilibrium effects become important for prediction of PICA ablation at heat flux or pressure below about 80 W/cm 2 and 10 kPa, respectively. In this work we investigate two modifications to the ablation model to account for these nonequilibrium effects. Model predictions are compared with the arcjet test data.
Engineering,Environmental Science,Materials Science,Physics
What problem does this paper attempt to address?