High throughput and very specific screening of anabolic-androgenic steroid adulterants in healthy foods based on stable isotope labelling and flow injection analysis-tandem mass spectrometry with simultaneous monitoring proton adduct ions and chloride adduct ions

Di Chen,Zi-Han Wang,Wei-Qi Cui,Jing-Xian Zhang,Jun-Wei Zhang,De-Qiao Wu,Zi-Yue Wang,Xin-Rui Yu,Yan-Bo Luo,Dilshad Hussain,Xia Xu
DOI: https://doi.org/10.1016/j.chroma.2022.462891
IF: 4.601
2022-03-01
Journal of Chromatography A
Abstract:In this work, a stable isotope labelling-flow injection analysis-tandem mass spectrometry (SIL-FIA-MS/MS) with simultaneous monitoring [M+H]<sup>+</sup> and [M+Cl]<sup>-</sup> method was developed for very specific and high throughput screening of anabolic-androgenic steroids (AAS) illegally added to healthy foods. Initially, a simple centrifugation step was carried out for liquid samples, and for solid samples, a solid-liquid extraction step was conducted. Afterwards, batch chemical derivatization was carried out. After adding a certain amount of <sup>13</sup>C<sub>6</sub>-3-NPH labelled AAS standards as the internal standards, it can be directly transferred for FIA-MS/MS analysis based on the no MS response characteristics of 3-NPH. The 3-NPH labelled AAS showed dual-polarity property, observing chloride adduct ion ([M+Cl]<sup>-</sup>) in negative ion mode and proton adduct ion ([M+H]<sup>+</sup>) in positive ion mode. The average time cost for pretreatment of each sample was less than 1 min by carrying out batch processing. The subsequent FIA-MS/MS detection enabled rapid and high throughput detection. The addition of <sup>13</sup>C<sub>6</sub>-3-NPH-labelled AAS as internal standards can correct the matrix effect to achieve accurate quantitative analysis. The detection sensitivity was also improved by 2-5 folds after 3-NPH labelling. The limits of detection (LODs) in positive MRM mode were in ranges of 0.1-0.3 ng/mL. The validated method with simultaneous monitoring [M+H]<sup>+</sup> and [M+Cl]<sup>-</sup> was validated in the range of 6.0-1000 ng/mL with the linear coefficient (R<sup>2</sup>) greater than 0.997. Satisfactory recoveries were found to be in ranges of 93.0-108.7%. The intra-day and inter-day RSDs were in the range of 3.5-9.9% and 5.1-14.1%, respectively. No changes in detection sensitivity of the mass spectrometry and no carry-over effects were found after numerous consecutive injections of AAS derivates. Compared with previously reported methods, the proposed method proved accurate, very specific, high throughput with good sensitivity.
chemistry, analytical,biochemical research methods
What problem does this paper attempt to address?