Quantifying flare combustion efficiency using a long wave infrared Fourier transform spectrometer

Paule Lapeyre,Nishant Sriram Narayanan,Martin Larivière-Bastien,Kyle J. Daun
DOI: https://doi.org/10.1016/j.proci.2024.105554
IF: 6.535
2024-07-26
Proceedings of the Combustion Institute
Abstract:In recent years, quantifying flare emissions has assumed new significance due to their impact on climate change and human health. Imaging Fourier transform spectrometers (IFTSs) operating over the infrared spectrum are a particularly promising avenue for this task since they can directly visualize the species column density contained within the entire flare plume via the absorption features of these species. These instruments generate a datacube of images, each pertaining to a unique wavelength. Spectroscopic and velocity submodels are then used to obtain the species mass flow rates needed to calculate the CE. This work compares the performance of mid-wavelength infrared (MWIR) and long-wavelength infrared (LWIR) IFTSs for measuring the CE for flares at petrochemical refineries, and, for the first time, uses a LWIR IFTS to fingerprint the plume species and estimate the CE. While the detection spectrum of the MWIR camera includes prominent CO2 features, the limited dynamic range of the camera leads to lens flare artifacts from the combustion zone that bias quantification of this species in the plume, thereby affecting the CE estimates. Images from the LWIR camera, in contrast, are free of these artifacts, and the dynamic range is sufficient to measure both CO2 and unburned fuel, key to accurate CE estimates.
energy & fuels,engineering, mechanical, chemical,thermodynamics
What problem does this paper attempt to address?