Advanced nitrogen removal from low carbon nitrogen ratio domestic sewage via continuous plug-flow anaerobic/oxic/anoxic system: Enhanced by endogenous denitrification
Huaguang Liu,Wenyi Dong,Zilong Zhao,Hongjie Wang,Zilong Hou,Yanchen Li,Zhiwei Zeng,Jin Xie,Fupeng Wang,Xueyon Liu,Yu Yan,Yanhui Qu
DOI: https://doi.org/10.1016/j.biortech.2023.128987
IF: 11.4
2023-04-02
Bioresource Technology
Abstract:An anaerobic/oxic/anoxic continuous plug-flow biorereactor was established to derive stable advanced nitrogen removal of oligotrophic domestic wastewater by setting a sludge dual-reflux system and a mixed liquid cross-flow system, while extending the hydraulic retention time in anoxic section. The effluent total inorganic nitrogen was 7.9 ± 2.2 mg N/L, with removal efficiency of 84 ± 3.9%. Results of nitrogen balance calculations indicated that the contribution of simultaneous nitrification and denitrification to total inorganic nitrogen loss in oxic region was 15% during stable stage, and the total inorganic nitrogen removal by endogenous-denitrification and enhanced exogenous-denitrification in the anoxic region was 39.9%. Prolongation of hydraulic retention time in anoxic segment is the critical reason for enhancing endogenous-denitrification, and cross-flow system is an important measure to improve exogenous-denitrification. This study provides new insights into bridging the gap between energy-saving and high-level nitrogen removal from municipal wastewater with low carbon to nitrogen ratios.
energy & fuels,biotechnology & applied microbiology,agricultural engineering