Enhanced Alzheimer's disease detection from MRI images using CycleGAN Augmentor, NeuroXt and XenonNet

Sharma, Prabhat
DOI: https://doi.org/10.1007/s11042-024-19077-z
IF: 2.577
2024-05-14
Multimedia Tools and Applications
Abstract:Alzheimer's disease (AD), a severe type of brain disease, can harm memory function and destroy brain tissue. Different deep learning-based systems have been presented to produce a high accuracy classifier to diagnose AD because AD is a generally expensive disease. The aim of this work is to improve AD diagnosis employing all-encompassing methodology that includes data enhancement, intelligent augmentation, sophisticated feature extraction, and novel deep learning architecture. To improve the quality of our dataset on Alzheimer's disease, data pre-processing methods like median filtering and histogram equalization are employed. This method successfully removes noise and artifacts, creating a solid base for further investigation. Optimized CycleGAN Augmentor, a Cycle-Consistent Generative Adversarial Networks (CycleGANs) is utilized for the data augmentation. The novel "NeuroXt" architecture, specifically created for Alzheimer's disease image analysis, is integrated with handcrafted classical features including Haralick features and Gabor filters during the feature extraction phase. A novel ensemble optimization model named "Wild Fusion Optimization Network (WFON)" is presented to find the most informative feature subset for classifying Alzheimer's disease. The WFON feature selection procedure combines the principles of several optimization algorithms, like Gorilla Troops Optimizer (GTO), Reptile Search Algorithm (RSA), and Raccoon Optimization Algorithm (ROA). The advanced ensemble model is rigorously deployed in the Alzheimer's disease detection phase, utilizing the meticulously optimized feature set. This ensemble model uses "XenonNet," a novel deep learning architecture created specifically for analyzing images of AD. XenonNet achieves an accuracy of 98.8%, highlighting its robustness and precision in correctly classifying instances of AD. Additional assessment metrics demonstrate the overall efficacy and resilience of the proposed approach, such as the low false negative rate (FNR) of 1.8%, the high Matthews correlation coefficient (MCC) of 97.3%, and the low false positive rate (FPR) of 0.9%.
computer science, information systems, theory & methods,engineering, electrical & electronic, software engineering
What problem does this paper attempt to address?