Comparative Study of Ultrasonic Vibration-Assisted Die-Sinking Micro-Electrical Discharge Machining on Polycrystalline Diamond and Titanium

Cheng Guo,Longhui Luo,Zhiqiang Liang,Hao Li,Xiawen Wang,Bin Xu
DOI: https://doi.org/10.3390/mi15040434
IF: 3.4
2024-03-26
Micromachines
Abstract:Die-sinking micro-electrical discharge machining (micro-EDM) is a potential method used to fabricate intricate structures without complex electrode motion planning and compensation. However, machining efficiency and poor discharge states are still bottlenecks. This study conducted a comparative investigation into the impact of ultrasonic vibration on die-sinking micro-EDM of polycrystalline diamond (PCD) and pure titanium (TA2). By adjusting discharge parameters, this study systematically evaluated the influence of ultrasonic vibration on these two materials based on discharge waveforms, motion trajectories, effective discharge counts and groove profiles. At an open-circuit voltage of 100 V, ultrasonic vibration promotes die-sinking micro-EDM of PCD. However, when the open-circuit voltage increases to 200 V, ultrasonic vibration exhibits inhibitory effects in general. Conversely, for TA2, ultrasonic vibration shows a promoting effect at both voltages, indicating the differences of ultrasonic vibration-assisted die-sinking micro-EDM on PCD and TA2. For PCD, ultrasonic cavitation improves the discharge gap environment, accelerating the removal of discharge debris. For TA2, due to its poor thermal conductivity, ultrasonic cavitation acts to break the arc, accelerating heat transfer. These research findings provide guidance for ultrasonic vibration-assisted die-sinking micro-EDM in industrial applications.
chemistry, analytical,nanoscience & nanotechnology,instruments & instrumentation,physics, applied
What problem does this paper attempt to address?
The problem that this paper attempts to solve is: in the die - sinking micro - EDM process, how to improve the machining efficiency and discharge state of two difficult - to - machine materials, polycrystalline diamond (PCD) and pure titanium (TA2), by introducing ultrasonic vibration. Specifically, the research aims to explore the influence of ultrasonic vibration on these two materials under different discharge parameters, including changes in discharge waveform, motion trajectory, effective discharge times, and groove profile. ### Research Background and Problem Description 1. **Characteristics of micro - EDM**: - Micro - EDM is an unconventional material removal method, widely used in the machining of high - hardness and difficult - to - machine materials, especially in the manufacturing of micro - parts. - Compared with micro - EDM milling, micro - EDM has the advantages of high efficiency and no need for complex electrode compensation. 2. **Existing problems**: - Although micro - EDM has the above - mentioned advantages, its low machining efficiency and poor discharge state are still bottlenecks. - Small discharge energy and electrode gap lead to difficulties in chip removal and flushing, so the introduction of ultrasonic vibration is expected to solve these problems. 3. **Research purposes**: - Compare the effects of ultrasonic vibration - assisted micro - EDM on PCD and TA2. - Explore the promoting or inhibiting effects of ultrasonic vibration under different voltage conditions and analyze its mechanism. ### Main Findings - **For PCD**: - When the open - circuit voltage is 100 V, ultrasonic vibration promotes the micro - EDM of PCD. - When the open - circuit voltage increases to 200 V, ultrasonic vibration generally shows an inhibitory effect. - Ultrasonic cavitation improves the discharge gap environment and accelerates the removal of discharge residues. - **For TA2**: - Ultrasonic vibration shows a promoting effect at both 100 V and 200 V voltages. - Due to the poor thermal conductivity of TA2, ultrasonic cavitation helps break the arc and accelerate heat transfer. These research results provide guidance for the industrial application of ultrasonic vibration - assisted micro - EDM. ### Conclusion This research reveals the complex effects of ultrasonic vibration in micro - EDM by systematically evaluating the influence of ultrasonic vibration on PCD and TA2 under different discharge parameters. The research results show that ultrasonic vibration can significantly improve machining efficiency and quality under specific conditions, but may also have an inhibitory effect in some cases. This provides important theoretical basis and practical guidance for optimizing the ultrasonic vibration - assisted micro - EDM process.