Loop-Mediated Isothermal Amplification for the Fast Detection of Bonamia ostreae and Bonamia exitiosa in Flat Oysters

Irene Cano,Gareth Wood,David Stone,Mathilde Noyer,Lydie Canier,Isabelle Arzul
DOI: https://doi.org/10.3390/pathogens13020132
IF: 3.7
2024-01-31
Pathogens
Abstract:The haplosporidian parasites Bonamia ostreae (BO) and B. exitiosa (BE) are serious oyster pathogens. Two independent laboratories evaluated fluorescence real-time loop-mediated isothermal amplification (LAMP) assays for rapidly detecting these parasites. Specific LAMP assays were designed on the BO actin-1 and BE actin genes. A further generic assay was conceived on a conserved region of the 18S gene to detect both Bonamia species. The optimal reaction temperature varied from 65 to 67 °C depending on the test and instrument. Melting temperatures were 89.8–90.2 °C, 87.0–87.6 °C, and 86.2–86.6 °C for each of the BO, BE, and generic assays. The analytical sensitivity of these assays was 50 copies/μL in a 30 min run. The BO and BE test sensitivity was ~1 log lower than a real-time PCR, while the generic test sensitivity was similar to the real-time PCR. Both the BO and BE assays were shown to be specific; however, the generic assay potentially cross-reacts with Haplosporidium costale. The performance of the LAMP assays evaluated on samples of known status detected positives within 7–20 min with a test accuracy of 100% for the BO and generic tests and a 95.8% accuracy for BE. The ease of use, rapidity and affordability of these tests allow for field deployment.
microbiology
What problem does this paper attempt to address?
This paper aims to develop loop - mediated isothermal amplification (LAMP) methods for the rapid detection of Bonamia ostreae (BO) and Bonamia exitiosa (BE) in flat oysters. These two parasites are serious oyster pathogens, causing bonamiosis, a disease that needs to be reported according to the regulations of the World Organisation for Animal Health (WOAH). In the paper, LAMP detection methods specific to the BO actin - 1 gene and the BE actin gene were designed, and a universal LAMP detection method for the 18S rRNA gene region was designed to simultaneously detect these two Bonamia species. The study evaluated the performance of these LAMP detection methods in different laboratories, including reaction temperature optimization, analytical sensitivity, specificity and diagnostic accuracy. The research results show that these LAMP detection methods have high sensitivity and specificity, can complete the detection within 30 minutes, and are suitable for on - site rapid detection applications.