Development of an Analytical Model for a Tuned Liquid Multi-Column Damper

Hao Wu,Liang Cao,An Chen,Simon Laflamme
DOI: https://doi.org/10.1061/9780784481899.079
2018-11-15
Abstract:Passive damping devices are frequently used to control building vibrations under extreme environments. Among them are tuned liquid column dampers, consisting of a large U-tube with oscillating liquid, which have been shown to be effective at mitigating structural responses under wind hazards. However, conventional tuned liquid column dampers are often large and space consuming, and are only effective under a fixed limited frequency bandwidth. In this paper, we build on previous studies and further investigate the concept of tuned liquid multi-column dampers, which allow liquid to flow through various vertical tubes connected via a horizontal tube to provide a higher operating bandwidth. A new analytical model characterizing the dynamic behavior is derived, validated using computational fluid dynamics. The model is used to study the effect of orifice size on a 4-column tuned liquid multi-column damper.
What problem does this paper attempt to address?