Hydrogen Storage in Deep Saline Aquifers: Non-Recoverable Cushion Gas after Storage

Katarzyna Luboń,Radosław Tarkowski
DOI: https://doi.org/10.3390/en17061493
IF: 3.2
2024-03-22
Energies
Abstract:Underground hydrogen storage facilities require cushion gas to operate, which is an expensive one-time investment. Only some of this gas is recoverable after the end of UHS operation. A significant percentage of the hydrogen will remain in underground storage as non-recoverable cushion gas. Efforts must be made to reduce it. This article presents the results of modeling the cushion gas withdrawal after the end of cyclical storage operation. It was found that the amount of non-recoverable cushion gas is fundamentally influenced by the duration of the initial hydrogen filling period, the hydrogen flow rate, and the timing of the upconing occurrence. Upconing is one of the main technical barriers to hydrogen storage in deep saline aquifers. The ratio of non-recoverable cushion gas to cushion gas (NRCG/CG) decreases with an increasing amount of cushion gas. The highest ratio, 0.63, was obtained in the shortest 2-year initial filling period. The lowest ratio, 0.35, was obtained when utilizing the longest initial filling period of 4 years and employing the largest amount of cushion gas. The presented cases of cushion gas recovery can help investors decide which storage option is the most advantageous based on the criteria that are important to them.
energy & fuels
What problem does this paper attempt to address?
The problem that this paper attempts to solve is how to reduce the amount of non - recoverable cushion gas (Non - Recoverable Cushion Gas, NRCG) when storing hydrogen in deep saline aquifers. Underground hydrogen storage facilities require cushion gas to maintain operation, which is a one - time and expensive investment. However, after the Underground Hydrogen Storage (UHS) operation is completed, only part of the cushion gas can be recovered, and the remaining part will stay in underground storage as NRCG. Therefore, reducing the amount of this part of NRCG is crucial for reducing the cost of hydrogen storage. The paper analyzes the cushion gas recovery process after the UHS operation through modeling, especially exploring the influence of the duration of the initial filling period, the hydrogen flow rate, and the occurrence time of the upconing (i.e., the phenomenon that the water level rises and causes water to enter the gas extraction well) on the amount of NRCG. The study found that the amount of NRCG is significantly affected by the above factors. Among them, the longer the initial filling period and the larger the amount of cushion gas used, the lower the proportion of NRCG. For example, the NRCG/CG ratio corresponding to the shortest initial filling period of 2 years is 0.63, while the ratio corresponding to the longest initial filling period of 4 years is only 0.35. These results help investors choose the most favorable storage plan according to their own important criteria, thereby optimizing the economic benefits of hydrogen storage facilities.