Utilization of Point-of-Care Ultrasound as an Imaging Modality in the Emergency Department: A Systematic Review and Meta-Analysis
Apurva Popat,Samyuktha Harikrishnan,Niran Seby,Udvas Sen,Sagar K Patel,Lakshay Mittal,Mitkumar Patel,Charitha Vundi,Yashasvi Patel,Babita .,Ashish Kumar,Akash A Nakrani,Mahir Patel,Sweta Yadav
DOI: https://doi.org/10.7759/cureus.52371
2024-01-16
Cureus
Abstract:Point-of-care ultrasound (POCUS) is an imaging modality that has become a fundamental part of clinical care provided in the emergency department (ED). The applications of this tool in the ED have ranged from resuscitation, diagnosis, and therapeutic to procedure guidance. This review aims to summarize the evidence on the use of POCUS for diagnosis and procedure guidance. To achieve this, CrossRef, PubMed, Cochrane Library, Web of Science, and Google Scholar databases were extensively searched for studies published between January 2000 and November 2023. Additionally, the risk of bias assessment was performed using the Quality Assessment of Diagnostic Accuracy Studies 2 (for studies on the diagnostic role of POCUS) and Cochrane Risk of Bias tool (for studies on the use of POCUS for procedure guidance). Furthermore, diagnostic accuracy outcomes were pooled using STATA 16 software (StatCorp., College Station, TX, USA), while outcomes related to procedure guidance were pooled using the Review Manager software. The study included 81 articles (74 evaluating the diagnostic application of POCUS and seven evaluating the use of POCUS in guiding clinical procedures). In our findings sensitivities and specificities for various conditions were as follows: appendicitis, 65% and 89%; hydronephrosis, 82% and 74%; small bowel obstruction, 93% and 82%; cholecystitis, 75% and 96%; retinal detachment, 94% and 91%; abscess, 95% and 85%; foreign bodies, 67% and 97%; clavicle fractures, 93% and 94%; distal forearm fractures, 97% and 94%; metacarpal fractures, 94% and 92%; skull fractures, 91% and 97%; and pleural effusion, 91% and 97%. A subgroup analysis of data from 11 studies also showed that the two-point POCUS has a sensitivity and specificity of 89% and 96%, while the three-point POCUS is 87% sensitive and 92% specific in the diagnosis of deep vein thrombosis. In addition, the analyses showed that ultrasound guidance significantly increases the overall success rate of peripheral venous access (p = 0.02) and significantly reduces the number of skin punctures (p = 0.01) compared to conventional methods. In conclusion, POCUS can be used in the ED to diagnose a wide range of clinical conditions accurately. Furthermore, it can be used to guide peripheral venous access and central venous catheter insertion.