Homograft implant for prosthetic aortic endocarditis with paravalvular abscess in a patient with persistent left superior vena cava

Martina Rizzo,Roberto Lorusso,Giuseppe Davoli,Daniele Marianello,Gianfranco Montesi,Sandro Gelsomino
DOI: https://doi.org/10.1510/mmcts.2024.042
2024-10-15
Abstract:We present a case report detailing the surgical intervention in a patient with prosthetic aortic valve endocarditis complicated by a paravalvular abscess extending to the mitral-aortic fibrosa. Urgent surgery was required due to severe detachment of the prosthetic aortic valve, marking her third cardiac surgical procedure. Notably, preoperative imaging revealed the presence of a persistent left superior vena cava, a rare vascular anomaly requiring specialized cannulation techniques. The surgical approach involved removal of the infected tissue and prosthetic valve, followed by replacement with a cryopreserved aortic homograft, chosen for its anatomical adaptability.