Finite element analysis of stabilization splint pressure distribution in a patient with disc displacement without reduction: A preliminary study

Acing Habibie Mude,Muhammad Ikbal,Mukhsan Putra Hatta,Irfan Sugianto,Edy Machmud,Fadhlil Ulum A Rahman,Imran Irsal,Eka Fibrianti,Muthia Mutmainnah Bachtiar,Thalib Rifky Abdullah Syeban Attamimi
DOI: https://doi.org/10.5624/isd.20240017
Abstract:Purpose: This study was performed to investigate the pattern of condylar pressure distribution in the discs of a patient diagnosed with disc displacement without reduction. Materials and methods: This research consisted of a pre- and post-test observational clinical study. A patient diagnosed with disc displacement without reduction underwent treatment with an occlusal splint for 3 months. Finite element analysis employed a 3-dimensional model constructed from magnetic resonance images of the patient, taken both before the application of the splint and 3 months after its use. Results: The post-test model demonstrated a decrease in condylar pressure on the disc, with measurements dropping to 72 MPa from the pre-test level of 143 MPa. In the pre-test, the pressure distribution pattern was concentrated on the lateral posterior border, whereas in the post-test, it shifted toward the intermediate zone of the disc. Conclusion: Utilization of a stabilization splint for 3 months resulted in decreased pressure and a marked change in the pressure distribution pattern on the temporomandibular disc.
What problem does this paper attempt to address?